digital audio
modular
processing system
C8000
Dolby Digital / Digtal plus / Pulse (AAC) encoder
C8612
7/20
DEVICE
Device Name You can assign a 16 character name to the module.
Press <CHANGE NAME> to store the name.
Platform Display of the hardware platform.
Parameter Version During the development new features will be added. This
requires to add parameters. The parameter version reflects a
curtain set of parameters.
FIRMWARE
Controller Firmware version of the module controller.
Dolby Firmware Version Version of the Dolby CAT561 OEM module.
Restart Module Pressing <RESTART> will warm start the C8612.
Initialize and Restore Pressing <INITIALIZE> will initialize the C8612 to factory
Factory Defaults defaults and will warm start the module afterwards.
Backup Settings and Pressing <BACKUP> will download all settings including the
Presets to File presets to a file that you can store on the PC.
Restore Settings and Pressing <RESTORE> after browsing and selecting a backup
Factory Defaults file, will move parameters and presets from that file back to the
module.