Reset Plot: will do what it says – you may reset the
measurement and start it again.
This will be prompted by a pop up.
? : a "Help" menu is not available yet.
The "About … " selection shows the
Junger Audio contact data, the software
version of the J*AM and presence of a valid
license for the Loudness Logging Tools.
The upper area of the live plot display offers a lot of detailed information and some setups you can also
find in the Display Option menu:
Module: device (single device) or c8k module name
Loudness Distribution: shows the loudness distribution of the short term values. This allows easy
estimation of how the levelling process can manage the desired target
compared to the source loudness distribution.
Program: [Program 2] name of the program that is measured by the live plot
Config: [2/0] configuration of the audio channels
Channel: [7 – 8] audio channels of the device or module used for that
program
Loudness Control Mode: [EBU R128] display of the actual loudness control mode of the
processor. You must not be confused by the loudness
measurement methods.
Integrated Loudness gated: [-25.8 / -22.2] loudness measurement - input vs. output using
ITU BS.1770-2 (gated)
LKFS Input/Output: unit of measurement for the integrated loudness
LKFS Input/Output ungated: [-27.4 / -23.2] loudness measurement – input vs. output using
ITU BS.1770-1 (ungated)
Loudness Range: [12.8 / 9.6]
LU Input/Output: unit of measurement for loudness range
Integr. Time: integration time of the EBU R128 program loudness
measurement
Comentarios a estos manuales