6
D*AP LM 4
Operating
Operating – menu structure of the Front Panel :
The display after power up – the idle display – shows the input "IN" and output "OUT" short term (3secs.)
loudness of the programs processed by the respective device channels. E.g.:
SHORT-TERM 3s
CH 1/2
IN
-70.0
OUT
-70.0
If you turn the RE the display will change to the True Peak Hold display of the respective channels:
TRUEPEAK-HOLD
CH 1/2
IN
-70.0
OUT
-70.0
And vice versa. If you press <SEL> you will see the values of the other processing channels.
Pressing <ESC> will reset the display reading (HOLD reset).
The 4 direct function buttons of the front panel will move you to the respective function blocks
where the RE selects the respective items.
<MODE> LOUDNESS MODE > SYNC SOURCE
< MUTE < ENABLE < LINK
<INPUT> INPUT GAIN > MONO > HP FILTER > LP FILTER > DELAY >
INPUT ROUTING BIT TRANSPARENT
< LINK
<LEVELER> ENABLE > LOUDNESS TARGET > TIME > MAX GAIN >
FREEZ LEVEL > TP MAX GAIN > TP RESPONSE > PROCESSING >
CLEAR HISTORY > INITIAL GAIN > THRESHOLD
<LIMITER> ENABLE > MAX TRUE PEAK > PROCESSING
The overall parameter menu structure is shown on the next page.