44
D*AP LM 4
Technical data
• Power supply optional dual power supply, auto fail over
AC 85 V – 264 V, 50 Hz … 60 Hz
58W max
• AES inputs BNC AES3id, 75 Ω, unbalanced, 24 Bit, 48 kHz, 0.32 … 1.2 Vpp
• AES inputs XLR AES3, 110 Ω balanced, 24 Bit, 48 kHz, 0.3 … 5.0 Vpp
Sample rate converters :
24 Bit, 32 kHz … 192 kHz, THD+N: < 130 dB @ 0 dBFS
Input auto selection :
between AES3id (leading) and AES3
• AES outputs BNC AES3id, 24 Bit, 48 kHz, nominal 1 Vpp @ 75 Ω
power fail relay bypass
• AES outputs XLR AES3, 3.3 Vpp @ 110 Ω
power fail relay bypass
Latency (AES I/O) 323 samples / 6,73 ms @ 48 kHz (all processing blocks active)
Force Minimal
Latency activated 194 samples / 4.04 ms @ 48 kHz (Spectral Signature disabled)
• Sync internal 48 kHz, +/- 10 ppm
• Sync input AES3id: 48 kHz, 0,32 … 1,2 Vpp @ 75 Ohm
Wordclock: 48 kHz, 1 V … 3 V @ 75 Ω
Video: Black Burst or Tri Level, 0.5 V … 1.0V @ 75 Ω
• Sync output Wordclock: 2 Vpp @ 75 Ω
• Network RJ45 rear connector
10/100MBit Ethernet auto sense, full duplex, auto MDI/X
• USB USB 2.0 "B" build in FTDI USB to RS232 converter
• GPI 5 V – 30 V balanced, auto polarity
• GPO relay change over contacts, 200 mA / 24 V (DC/AC)
• Environmental operating temperature 0 ºC to 50 ºC
Base Unit - fan cooled
non operating -20 ºC to 70 ºC
humidity 90%, non condensing
• Dimensions 19", 1RU, depth 27 cm
• Weight net weight approx. 4 kg, shipping weight 6,5 kg