Web GUI – AUDIO PROCESSOR – Output
Output – The final screen in this section allows for the adjustment of numerous audio parameters directly on
the final output signal.
Link [enable / disable]
Output [enable / disable]
Mute [on / off]
Attenuation (dB) [-80.0 … 0.0]
Mono [Stereo, L+R, LL, RR]
Output Delay (ms) [0 … 2.000]
Web GUI – EVENTS – Trigger – Trigger Configuration
EVENTS - In a broadcast facility, there are often requirements to integrate the Digital Audio Processor into
the automation system in order to facilitate functions such as remotely re-calling presets, firing GPO
commands etc. The events tab is where all relevant parameters can be set up.
A Trigger is the logical combination of up to two trigger sources. The Trigger may launch one or more
events. An event runs like a flip-book inside the D*AP. This powerful technology spans from simply recalling a
certain parameter to the complete reconfiguration of the LM 4. But it also enables several fail over scenarios
where the LM 4 will automatically react to the system and/or parameter status
Trigger – As a default, 8 standard trigger conditions are available. These can be configured to determine
actions resulting from combinations of hotkey, GPI, network commands, parameter values, active events,
other active trigger etc. stimulus :