D*AP8
19
Setup GUI – SYSTEM – Setup
Program Configuration [5.1 + 2 / 4 x 2]
Shows the program configuration (2 times 2 channel). This is also
the default configuration of the audio processing blocks.
Program Labels Each of the two possible programs has a name that will be used
Program 1 - 4 as a reference for the display of parameters and their setup.
Current Sync Source Status shows the status of the 5 tier sync priority circuit
Source active sync source
Sample Rate measured sample rate
Show detailed status [ON / OFF]
If you enable the checkbox you will get detailed information about
the measured rates of possible sync sources.
Sync Source Information