D*AP8
36
We see the labels assigned by the DanteController software in the "Channel" column:
Inputs 16 inputs are pre-defined for the Dante interface installed in a
D*AP8. They are organized in pairs and the input status is shown by
soft LEDs (green = PCM audio / yellow = non audio/ grey no audio).
Channel The labels assigned to that channel by the DanteController.
Connected The source of the audio signal.
Status [No Subscription / Subcription Unresolved / Wait / Naming Problem /
Loopback / Idle / Subscription in Progress / Connected (Unicast) /
Connected (Multicast) / Manual Config / Format Problem /
QoS Problem / Latency Problem / Clock Domain Problem /
Link Down / Fail / Unknown]
The Dante module provides very detailed status information. In
regular operation one will not see much of it.