Junger-audio D*AP8 Digital Audio Processor Manual de usuario Pagina 86

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 100
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 85
D*AP8
84
Setup GUI – EVENTS – Actions – Bypass Actions
The bypass action is bound to the <BYPASS> button of the X*AP RM
1
remote panel.
You must simply select "follow" or "-" in the setup field.
But it also allows you to turn the bypass on for, some or all function blocks by simply enabling the check
boxes in the right hand panel:
Triggered Bypass
Trigger
Source The X*AP RM1 <BYPASS> button is the trigger source
Lock Source [ON / OFF]
The X*AP RM
1
remote panel <BYPASS> button may be
disabled / enabled here.
Force Trigger Active [ON / OFF]
Force the bypass function from the GUI instead of the
X*AP RM
1
remote panel <BYPASS> button.
Bypass Event [4 x 2 / 5.1 + 2]
Programs [Input / Upmix / Filter – Spectral Signature / Filter – Equalizer /
Dynamics – Compressor / Voice Over / Level Magic – Leveler /
Level Magic –Limiter / Output]
AUX [Input]
Manual Bypass You can use the check boxes for manually bypassing the respective
function block of that program.
Vista de pagina 85
1 2 ... 81 82 83 84 85 86 87 88 89 90 91 ... 99 100

Comentarios a estos manuales

Sin comentarios